Multi-Split Systems - Small

Small Inverter Multi-Split System


MXZ VA Series - R410A

For space saving...Multiple indoor units can be connected to a single outdoor unit!

Our Inverter Multi-Split system models are designed to allow several indoor units (regardless of capacity or type) to be connected to a single outdoor unit. This allows you to select the model best suited to each and every room in your home. The inverter Multi-Split system enhances exterior aesthetics by reducing the number of outdoor units necessary, while also providing you with an easy and economical way of adding indoor units at any time.

MXZ-2A52VA-A2

Multi-Split system outdoor unit. (WxDxH, mm): 800 x 285 x 550. Cooling/Heating capacity: 5.2/6.4kW. Weight: 40kg. Requires a minimum combination of 2 and a maximum of 2 indoor units.

 

Multi-split
MXZ-3A54VA-A2  

Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 5.4/6.8kW. Weight: 57kg. Requires a minimum combination of 2 and a maximum of 3 indoor units.

 

Multi-split
MXZ-4A71VA-A2
 

Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 7.1/8.6kW. Weight: 58kg. Requires a minimum combination of 2 and a maximum of 4 indoor units.

 

Multi-split
MXZ-4A80VA-A2
 

Multi-Split system outdoor unit. (WxDxH, mm): 900 x 320 x 900. Cooling/Heating capacity: 8.0/9.4kW. Weight: 67kg. Requires a minimum combination of 2 and a maximum of 4 indoor units.

 

Multi-split
MXZ-4A80VA-A2
 

Multi-Split system outdoor unit. (WxDxH, mm): 900 x 320 x 900. Cooling/Heating capacity: 8.0/9.4kW. Weight: 67kg. Requires a minimum combination of 2 and a maximum of 4 indoor units.

 

Multi-split
MXZ-5A100VA
 

Multi-Split system outdoor unit. (WxDxH, mm): 900 x 320 x 900. Cooling/Heating capacity: 10.0/12.0kW. Weight: 68kg. Requires a minimum combination of 2 and a maximum of 5 indoor units.

 

Multi-split

 

Indoor units for MXZ VA Series

Select From a Wide Range of Stylish Indoor Units.

Select the best-suited Indoor Unit for your application from 22 models. You can choose a Indoor Unit from; Wall Mounted, Compact Floor, Ceiling Concealed, Ceiling Cassette or Ceiling Suspended.


Note when using these indoor heat pump units in a Multi-Split scenario, you will need to use a MXZ VA outdoor unit.

MSZ-FA25VA-A2

Plasma Duo Deluxe Wall mounted indoor unit - DC inverter heat pump with the i-see Sensor Area Setting, Plasma Deodorising & Plasma Duo Deluxe Wall mounted indoor unit - DC inverter heat pump with the i-see Sensor Area Setting, Plasma Deodorising & Air Filters and a Quick Clean Design. Comes with infra red remote and can be used with an optional PAR-21MAA 7 day controller. Cooling/Heating capacity: 2.5/3.2kW. (WxDxH, mm): 780 x 198 x 298. Weight: 10kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a MUZ-FA25VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
MSZ-FA35VA-A2  

Plasma Duo Deluxe Wall mounted indoor unit - DC inverter heat pump with the i-see Sensor Area Setting, Plasma Deodorising & Air Filters and a Quick Clean Design. Comes with infra red remote and can be used with an optional PAR-21MAA 7 day controller. Cooling/Heating capacity: 3.5/4.0kW. (WxDxH, mm): 780 x 198 x 298. Weight: 10kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a MUZ-FA35VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
MSZ-GA22VA-A2
 

Wall mounted indoor unit - DC inverter heat pump with infra red remote. Cooling/Heating capacity: 2.2/3.3kW. (WxDxH, mm): 780 x 210 x 298. Weight: 9kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. To be used on the MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System Only and is not available as a split system.

 

Multi-split
MSZ-GA25VA-A2
 

Wall mounted indoor unit - DC inverter heat pump with infra red remote. Cooling/Heating capacity: 2.5/3.2kW. (WxDxH, mm): 780 x 210 x 298. Weight: 9kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a MUZ-GA25VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
MSZ-GB35VA
 

Wall mounted indoor unit - DC inverter heat pump with infra red remote. Cooling/Heating capacity: 3.5/4.0kW. (WxDxH, mm): 780 x 210 x 298. Weight: 9kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a MUZ-GB35VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
MSZ-GB50VA
 

Wall mounted indoor unit - DC inverter heat pump with infra red remote. Cooling/Heating capacity: 5.0/5.6kW. (WxDxH, mm): 780 x 210 x 298. Weight: 9kg. Liquid / Gas Pipe (OD, mm): 6.35 / 12.7. Requires a MUZ-GB50VA outdoor unit or can be used in a customisable MXZ-3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
MSZ-GA60VA-A2  

Wall mounted indoor unit - DC inverter heat pump with infra red remote. Cooling/Heating capacity: 6.0/6.8kW. (WxDxH, mm): 1100 x 258 x 325. Weight: 16kg. Liquid / Gas Pipe (OD, mm): 6.35 / 15.88. Requires a MUZ-GA60VA outdoor unit or can be used in a customisable MXZ-4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
MSZ-GA71VA
 

Wall mounted indoor unit - DC inverter heat pump with infra red remote. Cooling/Heating capacity:7.1/8.1kW. (WxDxH, mm): 1100 x 258 x 325. Weight: 16kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a MUZ-GA71VA outdoor unit or can be used in a customisable MXZ-4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
MFZ-KA25VA
 

Compact Floor Console indoor unit - inverter heat pump with infra red remote. Cooling/Heating capacity: 2.5/3.4kW. (WxDxH, mm): 700 x 200 x 600. Weight: 14kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA25VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
MFZ-KA25VA-RC
 

Wall Recessed Compact Floor Console indoor unit - inverter heat pump with infra red remote. Cooling/Heating capacity: 2.5/3.4kW. (WxDxH, mm): 700 x 200 x 600. Weight: 14kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA25VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
MFZ-KA35VA
 

Compact Floor Console indoor unit - inverter heat pump with infra red remote. Cooling/Heating capacity: 3.5/4.0kW. (WxDxH, mm): 700 x 200 x 600. Weight: 14kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA35VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
MFZ-KA35VA-RC
 

Wall Recessed Compact Floor Console indoor unit - inverter heat pump with infra red remote. Cooling/Heating capacity: 3.5/4.0kW. (WxDxH, mm): 700 x 200 x 600. Weight: 14kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA35VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
MFZ-KA50VA
 

Compact Floor Console indoor unit - inverter heat pump with infra red remote. Cooling/Heating capacity: 4.8/6.0kW. (WxDxH, mm): 700 x 200 x 600. Weight: 14kg. Liquid / Gas Pipe (OD, mm): 6.35 / 12.7. Requires a SUZ-KA50VA outdoor unit or can be used in a customisable MXZ-3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
MFZ-KA50VA-RC
 

Wall Recessed Compact Floor Console indoor unit - inverter heat pump with infra red remote. Cooling/Heating capacity: 4.8/6.0kW. (WxDxH, mm): 700 x 200 x 600. Weight: 14kg. Liquid / Gas Pipe (OD, mm): 6.35 / 12.7. Requires a SUZ-KA50VA outdoor unit or can be used in a customisable MXZ-3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
SLZ-KA25VA
 

Compact Cassette indoor unit - DC inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 2.5/3.0kW. (WxDxH, mm): 570 x 570 x 208. Weight: 16.5kg, Panel 3kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA25VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
SLZ-KA25VAL
 

Compact Cassette indoor unit - DC inverter heat pump with infra red remote. Cooling/Heating capacity: 2.5/3.0kW. (WxDxH, mm): 570 x 570 x 208. Weight: 16.5kg, Panel 3kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA25VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
SLZ-KA35VA
 

Compact Cassette indoor unit - DC inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 3.5/4.0kW. (WxDxH, mm): 570 x 570 x 208. Weight: 16.5kg, Panel 3kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA35VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
SLZ-KA35VAL
 

Compact Cassette indoor unit - DC inverter heat pump with infra red remote. Cooling/Heating capacity: 3.5/4.0kW. (WxDxH, mm): 570 x 570 x 208. Weight: 16.5kg, Panel 3kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA35VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
SLZ-KA50VA
 

Compact Cassette indoor unit - DC inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 4.6/5.0kW. (WxDxH, mm): 570 x 570 x 208. Weight: 16.5kg, Panel 3kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA50VA outdoor unit or can be used in a customisable MXZ-3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
SLZ-KA50VAL
 

Compact Cassette indoor unit - DC inverter heat pump with infra red remote. Cooling/Heating capacity: 4.6/5.0kW. (WxDxH, mm): 570 x 570 x 208. Weight: 16.5kg, Panel 3kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA50VA outdoor unit or can be used in a customisable MXZ-3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
PLA-RP60BA
 

Ceiling cassette indoor unit - inverter heat pump with your choice of infra red remote or wired PAR-21MAA 7 day wall timer control. Optional: 360º i-See temperature sensor and an automatic elevating panel. Cooling/Heating capacity: 5.7/6.9kW. (WxDxH, mm): 840 x 840 x 258 (Panel: 950 x 950 x 35). Weight: 23kg + (Panel: 6kg). Liquid / Gas Pipe (OD, mm): 6.35 / 15.88. Requires a SUZ-KA60VA outdoor unit or can be used in a customisable MXZ-4A71, 4A80, 5A100, 8A140VA or PUHZ Multi-Split System.

 

Multi-split
PLA-RP71BA
 

Ceiling cassette indoor unit - inverter heat pump with your choice of infra red remote or wired PAR-21MAA 7 day wall timer control. Optional: 360º i-See temperature sensor and an automatic elevating panel. Cooling/Heating capacity: 7.1/8.0kW. (WxDxH, mm): 840 x 840 x 258 (Panel: 950 x 950 x 35). Weight: 23kg + (Panel: 6kg). Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP71VHA outdoor unit or can be used in a customisable MXZ-4A80, 5A100, 8A140VA or PUHZ Multi-Split System.

 

Multi-split
SEZ-KD35VA
 

Ceiling Concealed indoor unit - DC inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 3.5/4.0kW. (WxDxH, mm): 900 x 700 x 200. Weight: 21kg. Liquid / Gas Pipe (OD, mm): 6.35 / 9.52. Requires a SUZ-KA35VA outdoor unit or can be used in a customisable MXZ-2A52, 3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
SEZ-KD50VA
 

Ceiling Concealed indoor unit - DC inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 5.0/6.0kW. (WxDxH, mm): 900 x 700 x 200. Weight: 23kg. Liquid / Gas Pipe (OD, mm): 6.35 / 12.7. Requires a SUZ-KA50VA outdoor unit or can be used in a customisable MXZ-3A54, 4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
SEZ-KD60VA
 

Ceiling Concealed indoor unit - DC inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 5.5/7.0kW. (WxDxH, mm): 1100 x 700 x 200. Weight: 27kg. Liquid / Gas Pipe (OD, mm): 6.35 / 15.88. Requires a SUZ-KA60VA outdoor unit or can be used in a customisable MXZ-4A71, 4A80, 5A100 or 8A140VA Multi-Split System.

 

Multi-split
PCA-RP50GA
 

Ceiling suspended indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 4.7/5.5kW. (WxDxH, mm): 1000 x 680 x 210. Weight: 27kg. Liquid / Gas Pipe (OD, mm): 6.35 / 12.7. Requires a SUZ-KA50VA outdoor unit or can be used in a customisable MXZ-3A54, 4A71, 4A80, 5A100VA or PUHZ Multi-Split System.

 

Multi-split
PCA-RP60GA
 

Ceiling suspended indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 5.5/6.9kW. (WxDxH, mm): 1310 x 680 x 210. Weight: 34kg. Liquid / Gas Pipe (OD, mm): 6.35 / 15.88. Requires a SUZ-KAz60VA outdoor unit or can be used in a customisable MXZ-4A71, 4A80, 5A100VA or PUHZ Multi-Split System.

 

Multi-split
PCA-RP71GA
 

Ceiling suspended indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 7.1/8.0kW. (WxDxH, mm): 1310 x 680 x 210. Weight: 34kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP71VHA outdoor unit or can be used in a customisable MXZ-4A80, 5A100VA or PUHZ Multi-Split System.

 

Multi-split
PEA-RP71EA
 

Ducted / ceiling-concealed indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 7.1/8.0kW. (WxDxH, mm): 785 x 690 x 428. Weight: 46kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP71VHA outdoor unit or can be used in a customisable MXZ-4A80VA-A2, 5A100VA, 8A140VA or PUHZ Multi-Split System.

 