Multi-Split Systems - large

 

Large Inverter Multi-Split System

PUHZ-RP/BP YHA Series - R410A

PUHZ-RP/BP YHA Series outdoor multi units can be used as a Twin (2x 7.1kW or 2x 10.0kW or 2x 12.5kW) or as a Triple (3x 7.1kW) or as a Quadruple (4x 5.0 or 6.0kW) system when connecting with the Distribution Pipe Kit.

PUHZ-BP200YHA

Outdoor unit for PEA-RP200WGA and also for use as a Large Multi-Split system. (WxDxH, mm): 950 x 330(+30) x 1350. Cooling/Heating capacity: 19.0/22.4kW. Three (3) phase. Weight: 126kg. Liquid / Gas Pipe (OD, mm): 9.52 / 25.4. When being used as a Twin (2x 10.0kW) or Quadruple (4x 5.0kW) Multi-Split system a Twin (MSDD-50WR-E) or Quadruple (MSDF-1111R-E) Distribution Pipe Kit is needed.

 

Multi-Split
PUHZ-RP250YHA
 

Outdoor unit for PEH-RP250MYA and also for use as a Large Multi-Split system. (WxDxH, mm): 900 x 750 x 1798. Cooling/Heating capacity: 22.0/27.0kW. Three (3) phase. Weight: 198kg. Liquid / Gas Pipe (OD, mm): 12.7 / 28.58. When being used as a Twin (2x 12.5kW) or Triple (3x 7.1kW) or Quadruple (4x 6.0kW) Multi-Split system either a Twin (MSDD-50WR-E) or Triple (MSDT-111R-E) or Quadruple (MSDF-1111R-E) Distribution Pipe Kit is needed.

 

Multi-Split
MSDD-50WR-E
 

Twin Distribution Pipe Kit for a 50:50 system split. PUHZ-RP200YHA outdoor unit when connecting (2x 10.0kW indoor units). PUHZ-RP250YHA outdoor unit when connecting (2x 12.5kW indoor units).

 

 
MSDT-111R-E
 

Triple Distribution Pipe Kit for a 33:33:33 system split. PUHZ-RP140VHA outdoor unit when connecting (3x 5.0kW indoor units). PUHZ-RP250YHA outdoor unit when connecting (3x 7.1kW indoor units).

 

 
MSDF-1111R-E
 

Quadruple Distribution Pipe Kit for a 25:25:25:25 system split. PUHZ-RP200YHA outdoor unit when connecting (4x 5.0kW indoor units). PUHZ-RP250YHA outdoor unit when connecting (4x 6.0kW indoor units).

 

 

 

Indoor units for PUHZ-RP/BP YHA Series

When using these indoor heat pump units in a Multi Split scenario, you will need to use a Twin (MSDD-50WR-E) Distribution Pipe Kit for a 50:50 split or a Triple (MSDT-111R-E) Distribution Pipe Kit for a 33:33:33 split or a Quadruple (MSDF-1111R-E) Distribution Pipe Kit for a 25:25:25:25 split.

PKA-RP71FAL

Wall mounted indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 7.1/8.0kW. (WxDxH, mm): 1400 x 235 x 340. Weight: 24kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP71VHA outdoor unit or can be used in a customisable PUHZ Multi-Split System.

 

Multi-Split
PKA-RP100FAL
 

Wall mounted indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 10.0/11.2kW. (WxDxH, mm): 1680 x 235 x 340. Weight: 28kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP100VHA deluxe, PUHZ-BP100VHA standard outdoor unit or can be used in a customisable PUHZ Multi-Split System.

 

Multi-Split
PLA-RP60BA
 

Ceiling cassette indoor unit - inverter heat pump with your choice of infra red remote or wired PAR-21MAA 7 day wall timer control. Optional: 360º i-See temperature sensor and an automatic elevating panel. Cooling/Heating capacity: 5.7/6.9kW. (WxDxH, mm): 840 x 840 x 258 (Panel: 950 x 950 x 35). Weight: 23kg + (Panel: 6kg). Liquid / Gas Pipe (OD, mm): 6.35 / 15.88. Requires a SUZ-KA60VA outdoor unit or can be used in a customisable MXZ-4A71, 4A80, 5A100, 8A140VA or PUHZ Multi-Split System.

 

Multi-Split
PLA-RP71BA
 

Ceiling cassette indoor unit - inverter heat pump with your choice of infra red remote or wired PAR-21MAA 7 day wall timer control. Optional: 360º i-See temperature sensor and an automatic elevating panel. Cooling/Heating capacity: 7.1/8.0kW. (WxDxH, mm): 840 x 840 x 258 (Panel: 950 x 950 x 35). Weight: 23kg + (Panel: 6kg). Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP71VHA outdoor unit or can be used in a customisable MXZ-4A80, 5A100, 8A140VA or PUHZ Multi-Split System.

 

Multi-Split
PLA-RP100BA
 

Ceiling cassette indoor unit - inverter heat pump with your choice of infra red remote or wired PAR-21MAA 7 day wall timer control. Optional: 360º i-See temperature sensor and an automatic elevating panel. Cooling/Heating capacity: 10.0/11.2kW. (WxDxH, mm): 840 x 840 x 298 (Panel: 950 x 950 x 35). Weight: 30kg + (Panel: 5kg). Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP100VHA deluxe, PUHZ-BP100VHA standard outdoor unit or can be used in a customisable PUHZ Multi-Split System.

 

Multi-Split
PLA-RP125BA
 

Ceiling cassette indoor unit - inverter heat pump with your choice of infra red remote or wired PAR-21MAA 7 day wall timer control. Optional: 360º i-See temperature sensor and an automatic elevating panel. Cooling/Heating capacity: 12.5/14.0kW. (WxDxH, mm): 840 x 840 x 298 (Panel: 950 x 950 x 35). Weight: 32kg + (Panel: 5kg). Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP125VHA deluxe, PUHZ-BP125VHA standard outdoor unit or can be used in a customisable PUHZ Multi-Split System.

 

Multi-Split
PCA-RP50GA
 

Ceiling suspended indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 4.7/5.5kW. (WxDxH, mm): 1000 x 680 x 210. Weight: 27kg. Liquid / Gas Pipe (OD, mm): 6.35 / 12.7. Requires a SUZ-KA50VA outdoor unit or can be used in a customisable MXZ-3A54, 4A71, 4A80, 5A100VA or PUHZ Multi-Split System.

 

Multi-Split
PCA-RP60GA
 

Ceiling suspended indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 5.5/6.9kW. (WxDxH, mm): 1310 x 680 x 210. Weight: 34kg. Liquid / Gas Pipe (OD, mm): 6.35 / 15.88. Requires a SUZ-KAz60VA outdoor unit or can be used in a customisable MXZ-4A71, 4A80, 5A100VA or PUHZ Multi-Split System.

 

Multi-Split
PCA-RP71GA
 

Ceiling suspended indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 7.1/8.0kW. (WxDxH, mm): 1310 x 680 x 210. Weight: 34kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP71VHA outdoor unit or can be used in a customisable MXZ-4A80, 5A100VA or PUHZ Multi-Split System.

 

Multi-Split
PCA-RP100GA
 

Ceiling cassette indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 10.0/11.2kW. (WxDxH, mm): 1310 x 680 x 270. Weight: 37kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP100VHA deluxe, PUHZ-BP100VHA standard outdoor unit or can be used in a customisable PUHZ Multi-Split System.

 

Multi-Split
PCA-RP125GA
 

Ceiling cassette indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 12.5/14.0kW. (WxDxH, mm): 1620 x 680 x 270. Weight: 43kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP125VHA deluxe, PUHZ-BP125VHA standard outdoor unit or can be used in a customisable PUHZ Multi-Split System.

 

Multi-Split
PEA-RP71EA
 

Ducted / ceiling-concealed indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 7.1/8.0kW. (WxDxH, mm): 785 x 690 x 428. Weight: 46kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP71VHA outdoor unit or can be used in a customisable MXZ-4A80VA-A2, 5A100VA, 8A140VA or PUHZ Multi-Split System.

 

Multi-Split
PEA-RP100EA2
 

Ducted / ceiling-concealed indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 10.0/11.2kW. (WxDxH, mm): 1055 x 690 x 428. Weight: 59kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP100VHA deluxe, PUHZ-BP100VHA standard outdoor unit or can be used in a customisable PUHZ Multi-Split System.

 

Multi-Split
PEA-RP125EA
 

Ducted / ceiling-concealed indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 12.5/14.0kW. (WxDxH, mm): 1255 x 690 x 428. Weight: 72kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP125VHA deluxe, PUHZ-BP125VHA standard outdoor unit or can be used in a customisable PUHZ Multi-Split System.

 

Multi-Split